HR17B series fuse-switch disconnector,is applied to circuit of rated current 40A to 630A.It has 2P,3P and 4P.And it can operate with load.It has 2P,3P,4P.And It canbe installed by hunging on the busbar, can also be installed on the fixed board.And it provides the upper and lower terminals for input and output,with a knife edge introduction and arc extinguishing device.And shell cover has the sealed detect hole which install signal switch,detect switch inside. And it can be used as knife switch by equiping fuse monitor.
This product conforms to standard of IEC60947-3,GB14048.3.
Normal operational conditions and installation conditions
3.1 Temperater: no higher than +40ºC,and no lower than -5ºC,and the day average temperature no higher than +35ºC.
3.2 Altitude: no higher than 2000m
3.3 The relative humidity: no more than 50%,when temperature is +40ºC.The product can withstand higher humidity under lower temperature,for instance,when it at +20ºC,the production can withstand 90% relative humidity.
The condensation that happened because of temperature changes should be taken care.
And Installation location should have no exploresion danger, and no gas and conductive dust which can cause corrosion and insulation damage.
3.4 Class of pollution: 3 Calss
3.6 Installation type:III, IV.
For more details and information, please contact us.
Main technical parameter
Model No. | HR17B-40 | HR17B-63 | HR17B-160 | HR17B-250 | HR17B-400 | HR17B-630 |
Rated insulation voltage Ui | 690V | 690V | 690V | 690V | 690V | 690V |
Rated operate voltage Ue | 400V | 400V | 400V | 400V | 400V | 400V |
Rated operate current Ie | 40A | 63A | 160A | 250A | 400A | 630A |
Rated short-circuit making capacity | 400A | 630A | 1600A | 2500A | 4000A | 6300A |
Rated ultimate short-circuit current Inc | 50kA | 50kA | 50kA | 50kA | 50kA | 50kA |
Use type | AC-23B | AC-23B | AC-23B | AC-23B | AC-23B | AC-23B |
Fuse(match) | RT14-40 (14 x 51) |
RT14-63 (22 x 58) |
NT00-160 | NT1-250 | NT2-400 | NT3-630 |
Actual images of the product are as followings:
Actual image of the parts:
FAQÂ - DHECNÂ
1.Question: Are you a manufacturer or trading company ?Â
Answer: We are a specical manufacturer with import & export license, which established in 1998, it is a professional manufacturer in designing, producing and selling isolation switch, switching power supply, current transformer, voltage transformer, and other electrical products.
2. Question : Why choose us and trust us? Â
Answer :Â Â Good product, good price, and good service.
Company spirit: Practical innovation, sincerity to all
Core values: Customers' praise is the only value we exist.
Management concept: Pursuing excellent quality, creating first-rate services
3. Question : Where is your factory located ?  How can I visit there ?   Â
Answer: With an ISO90001 certified factory located in Yueqing city, Zhejiang Province, P.R.OF China. It takes about 4 hours from SHANGHAI by high-speed rail and 45 minute by air.
It is very pleasure for all to visit us.Â
Â
4. Question :Â Can you do OEM ?Â
Answer: Yes, we have the ability to do OEM /ODM to meet your requirements.Â
Â
5. Question :Â What is the payment terms?
Answer: In general T/T, L/C, Paypal or others we can discuss.
Â
6. Question :How about the delivery time?
Answer: Usually, if have enough in warehouse, the delivery time is within 3 working days.
If need produce, the lead time is about 10-20 working days according to quantity of the order.
Â
7. Question :Â How about the shipping method?
Answer: For sample or small order, deliver by International express, such as DHL, FEDEX, TNT, UPS, EMS and so on.
For large order, deliver by sea or by air according to buyers shipping instructions.
Â
How to contact usÂ
Â
Send your Inquiry Details in the Below, please Click "Send" Now!
Good price and sample are waiting for you.
Â
Silicone rubber insulation cover is an insulation safety protection product that must be used for wiring terminals of power equipment such as transformers, lightning arresters and outdoor disconnecting switches. The product can effectively prevent the original exposed power equipment wiring end due to various reasons (human contact, animal or sundry wiring 5) caused by short circuit or contact caused by power failure, damage to power equipment and electric shock and other accidents.
The general wiring methods for this Transformer Connector Shield includes clamp type and terminal type. The users make orders according to the transformer inlet and outlet lines.
Features:
1.Suitable for 1-35KV.
2.Radiation cross linking materials (Polyolefin or EPDM rubber ).
3.Quick and easy installation.
4.Avoid short circuit and leakage.
5.Facilitate routine inspection and maintenance.
6.Resistant to moisture and dust.
7.Meet RoHS Stand.
8.Customized.
We are the professional manufacturer of Electrical Tapes,Insulating Tape and Bushing Cover in China for more than 25 years,if you want to know more information about our company and products, please visit our website.
Bushing Cover For Transformer,Transformer Bushing Covers,Bushing Cover Transformer,Cover Bushing Trafo
CAS Applied Chemistry Materials Co.,Ltd. , https://www.casac1997.com