BET big battle - Huaqiang Electronic Network

Brand AVX TPSE226M035R0125 Low impedance tantalum capacitor AVX 22
Electronic scale crystal oscillator 3.2*2.5mm 3225 16M (16.000MHZ) 12PF 10PPM 20PPM 30PPM
Probe current voltage pin 420*4450 head diameter 5.0 over current current and voltage pin
Huaqiang Square crystal original spot stock

For some materials, its surface area is one of its important physical properties, and directly affects its performance during use, such as: catalyst materials, battery materials, pharmaceutical raw materials and so on. However, the surface structure of the material is extremely complicated, so we need to determine the surface of the material by certain methods. Common methods for measuring surface area include: gas adsorption,

X

Suspected of small angle diffraction method, direct measurement method, etc. Different methods use different methods, and the general method is gas adsorption.

Researchers have conducted many theoretical studies on the possibility of gas adsorption for measuring surface area, among which

Brunauer

,

Emmett

with

Teller

The proposed model and calculation formula are the most famous, called

BET

law. Currently

BET

The method is the standard method for workers to measure the surface area of ​​solids and is the most common method.

BET

The method calculates the surface area per unit mass of the material, also known as the specific surface area, in units

m 2 /g

.

It is well known that the gas adsorption method tests the gas adsorption amount of a material under a plurality of different relative pressures under isothermal conditions, and after such a point is connected, an isothermal adsorption-desorption curve is formed. Specific surface area is measured on an isothermal adsorption curve

3-5

a point, use

BET

The equation is calculated and calculated. So the question is, what kind of point calculation is used to calculate the specific surface area is meaningful?

According to theory and long-term practice, currently prescribed

BET

The selection range is

P/P 0 : 0.05-0.3

. But for different samples, this interval will also need to be changed. Especially microporous materials. In general, microporous materials are used in calculations.

BET

The point will be relatively small relative pressure, the common is in relative pressure

10-3

Within the interval, even smaller. No matter which interval the selection point is, be sure to ensure

C

The value is positive and the correlation coefficient is

0.999

the above. As long as these two points are guaranteed, the obtained specific surface area value is meaningful.

Well, the problem is coming again. Within the above range, we are guaranteeing

C

Positive value and correlation coefficient at

0.999

Above, there may be different specific surface values, which one is right? The answer is, as long as the above two conditions are guaranteed,

BET

The value is a valid value. If you want to compare with other data, try to ensure that the points are consistent.

These years

BET

Are you right?

Air Conditioner Controller PCBA

Controller Pcb Board ,Pcba Assembly,Pcba Controller Board,Conditioner Controller Pcba

Full Industrial CO.,ltd. , https://www.iotaindustrial.com

Posted on